Home

 Predict® NAVIGATORTM

Used Oil Contaminant Screening Tool

Specifications

¼³ºñ³ª ±â°è¸¶´Ù »ç¿ëÁßÀÎ ¿ÀÀÏ.À±È°À¯ÀÇ °íÀ¯Æ¯¼ºÀÎ ¼öºÐÈ­/±Ý¼Ó¼º¸¶¸ðÀÔÀÚ¾ç/»êÈ­µµÀÇ Çã¿ëÄ¡¸¦ °èÃø±â¿¡ ¼³Á¤ÇÏ¿©, »ç¿ëÀ¯ÀÇ O.K./NOT  O.K.ÀÇ °á°ú¸¦ °£ÆíÈ÷ ÃøÁ¤.  

°èÃø±âÀÇ »ó´Ü¿¡ ÀÖ´Â °ÍÀÌ PREDICT»ç°¡ °³¹ßÇÑ Æ¯¼ö¼¾¼­·Î, 4°³ÀÇ Á֯ļö·Î ºñ»ç¿ëÀ¯¿Í »ç¿ëÀ¯ÀÇ º¯È­Ä¡¸¦

¼¾¼­¿¡ ¾ñ¾î¼­ ÃøÁ¤ÇÔ.  µû·Î ½Ã·á°¡ ÇÊ¿ä¾øÀÌ, Æò¹üÇÑ Å¬¸®´× ŰƮ·Î ´Û¾Æ ³»¾î, Àå±â°£ ¼¾¼­¸¦ »ç¿ëÇÔÀ¸·Î, ´Ù¸¥ ÈÞ´ë¿ë

¿ÀÀÏ ºÐ¼®±â°¡ ¿©·¯ °¡Áö ½Ã·á¸¦ »ç¿ëÇÏ´Â ¹æ½ÄÀ» »ç¿ëÇÔÀ¸·Î¼­ °èÃø±â ±¸¸ÅÈÄ, ½Ã·á ±¸¸Åºñ¿ë¿¡ ¾î·Á¿òÀ» °ÞÀ» Çʿ䰡

¾ø´Â °æÁ¦ÀûÀÎ °èÃø±âÀÓ.

 

°£´ÜÇÑ Àåºñ °³¿ä                                                                  »ó¼¼ÇÑ ÀÚ·á

Size/Weight:                       
-  Length, width, depth: 7.0 in. (17.8 cm), 3.2 in. (8.1 cm),  1.5 in. (3.8 cm)
-  Weight: 19.2 oz. (0.54 kg)

Contaminant Sensitivity *

¼öºÐÈ­/ÀÚ¼º¸¶¸ðÀÔÀÚ/»êÈ­µµÀÇ º¯È­¸¦ ¾Æ·¡¿Í °°Àº ±âÁØÄ¡·Î ¼¾¼­¿¡ ¼³Á¤Çϰí, ¾Æ·¡ °ªº¸´Ù ³·Àº º¯È­ ¼öÄ¡´Â

"OK" ¿¡ ÀÇÇØ °è¼Ó »ç¿ë°¡´ÉÀ» ¾Ë¸®°í, º¯È­Ä¡°¡ ¾Æ·¡ °ªº¸´Ù ³ôÀ¸¸é, "OUT OF LIMITS"¿¡ ÀÇÇØ ´Ù½Ã Á¤¹Ð °Ë»çÇÏ¿©¾ß ÇÔ.

 Á¤¹ÐÀ¯ ȤÀº °ÅÄ¥°Ô »ç¿ë°¡´ÉÇÑ ¿ÀÀÏÀÇ °æ¿ì  ¼³Á¤Ä¡¸¦ ±âÁØ¿¡ ¸Â°Ô º¯°æ ½ÃÄÑÁÙ ¼ö ÀÖ´Ù.

 

-  Water:
   100 ppm or higher (Karl Fischer coulometric)

 

-  Wear Metals:
   120 ppm or higher (RDE Spectrometer)

 

-  Detects changes in the lubricant attributed to 7AU of oxidation or higher    (FTIR spectrometer    transmission cell)
 

I2 Sensor
-  Self calibrating
-  Ambient temperature compensation
-  Teflon substrate ensures stability in high humidity environments
-  Solvent resistant sensor is ready for reuse immediately after cleaning

Processor
-  Dual Processors V20H/80C88 & 68HC11E9
-  8 MHz clock rate
-  1 MB of RAM, able to store a combination of 150 sample points and 650 analysis
    
(i.e. A company with 10 reference oils and 100 pieces of equipment; Navigator will store more than 1/2 year      of monthly analysis before uploading to computer.)
-  Typical analysis time is 4 minutes per sample

Power
-  Three AA rechargeable NiCd batteries
-  Fail-safe power backup maintains data
-  AC charger 115 VAC or 220 VAC

Communications
-  Two way via built-in RS-232 port
-  Asynchronous up to 38 kbps

Environmental
-  Operating Temperature range:32º to 100º F (0º to 49º C)
-  Storage Temperature range:-20º to 160º F (-28º to 71º C)
-  ESD to 15 kV (ElectroStatic Discharge)

Keyboard
-  Full 24-key numeric and special functions

Display
-  4-line x 16-character graphic LCD
-  High contrast display

Support Software
-  Data base setup
-  Trend plot display
-  Report generation
-  User defined alarm thresholds
-  Exchange PredictNAVIGATOR database and lab results with PREDICT/DLI'S Analysis laboratory
-  Receive lab results via internet, e-mail, or direct modem connection

Lubricant Applicability
-  Analyzes most common industrial lubricating oils
-  Alerts user if a non-supported reference sample is analyzed

*  Sensitivity levels were established by comparing PredictNAVIGATOR results to recognized laboratory testing methods.  PredictNAVIGATOR is a qualitative comparison trending device, not a quantitative measurement unit.  Although, PredictNAVIGATOR's measurement results can correlate to various associated levels of particular contaminants, it should be used as a screening tool not as a replacement for professional laboratory analysis.

 

Çѹ̻ê¾÷ 

ÀüÈ­ :  02 - 3411- 0173    ÆÑ½º :  02 - 3411 - 0178

sales@gohanmi.com

2001-2005 Hanmi Industries Ltd. All rights reserved
sales@gohanmi.com